Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Voltage Set meter to measure AC Volts
Remove R/H cover plate
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow fan to run and ignition sequence to commence.
Measure voltage across the brown wire (marked GVL) and the blue wire (marked GVN) at the connector marked CON 2 on ignition control board.
Note:
Voltage will only be present for approximately 7 seconds after the fan has completed its purge period (purge period lasts about 7 seconds from when fan starts).