Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Remove cover from PCB
Attach U-gauge to burner pressure test point
Safely connect a link between pin 1 and 2 on terminal X4a
Turn Pot P6 fully clockwise, making a note of its original position
DHW temperature set to MAX
Selector Switch in Hot Water Position
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Once the boiler has lit and established, make a note of the burner pressure then turn potentiometer P3 fully clockwise.
Burner pressure should be approximately 1.4mb.
Turn potentiometer P3 fully anti-clockwise.
Burner pressure should increase to approximately 9.5mb.
Turn potentiometer P3 back to its original position / burner pressure.