Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Remove cover from PCB
Connect a link between pin 1 and 2 on terminal X4a
Selector Switch in Hot Water Position
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Once the boiler has lit and established, turn potentiometer P3 fully clockwise.
Measure the voltage between the red wire marked 2
and the violet wire marked 1 on X6 connector at the PCB.
Voltage should be approximately 26V DC.

Turn potentiometer P3 fully anti-clockwise.
Measure the voltage again between the red and violet wires.
Voltage should now be approximately 43V DC.