Set Appliance State:

Mains Power Off
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Selector switch in Hot Water Position
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure for mains voltage between the
red wires connected to the fan terminals.