Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
Selector Switch in Hot Water Position
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Once the boiler begins its ignition sequence (pump starts to run), monitor the voltage between X8 (flame sense lead) at the PCB and a suitable earth point.
Voltage should be approximately 140V AC.
Once the burner ignites the voltage should drop to 135V AC or lower.
Note:
Some voltage may be present with no demand however this is not relevant to the test.
Voltage should be approximately 140V AC.
Once the burner ignites the voltage should drop to 135V AC or lower.
Note:
Some voltage may be present with no demand however this is not relevant to the test.