Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect plug for pins 10-15 from the PCB
Measurement:
Test 1:
Measure the resistance between the two
violet wires (10 & 11) on the disconnected plug.
Resistance should be approximately 4.2 kOhms.
Test 2:
Measure the resistance between each of the violet wires
(10 & 11) on the disconnected plug to a suitable earth point.
Resistance should be greater than 1MOhm on both tests.
Measure the resistance between the two
violet wires (10 & 11) on the disconnected plug.
Resistance should be approximately 4.2 kOhms.
Test 2:
Measure the resistance between each of the violet wires
(10 & 11) on the disconnected plug to a suitable earth point.
Resistance should be greater than 1MOhm on both tests.

Isolate as per TOPs P4
and refit as necessary