Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between the white wires (30 & 31) at the right hand plug on the PCB.
During the sparking stage of the ignition sequence
approximately 10-15V DC should be measured.
During the sparking stage of the ignition sequence
approximately 10-15V DC should be measured.

Isolate as per TOPs P4
and refit as necessary