Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect plug for pins 1-5 from the PCB
Measurement:
Test 1:
Measure the resistance between the brown wire marked L and blue wire marked N on the mains inlet terminal block.
Resistance should be greater than 1M Ohm.
Test 2:
Measure between the brown wire marked L and the earth on the mains inlet plug
Resistance should be greater than 1M Ohm.
Measure the resistance between the brown wire marked L and blue wire marked N on the mains inlet terminal block.
Resistance should be greater than 1M Ohm.
Test 2:
Measure between the brown wire marked L and the earth on the mains inlet plug
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary