Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove pump cover
Remove wires from pump connections
Remove wires from pump connections
Measurement:
Test 1:
Measure the resistance between the L and N connections at the pump.
Resistance should be approximately 160 Ohms or greater.
Test 2:
Measure the resistance between the L and earth connections at the pump.
Resistance should be greater than 1MOhm.
Measure the resistance between the L and N connections at the pump.
Resistance should be approximately 160 Ohms or greater.
Test 2:
Measure the resistance between the L and earth connections at the pump.
Resistance should be greater than 1MOhm.

Isolate as per TOPs P4
and refit as necessary