Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect wire marked COM or C from the air pressure switch
Measurement:
Measure the resistance between the common and normally closed terminals of the air pressure switch.
Resistance should be short circuit (zero resistance).
Note:
Design of APS may differ but test remains the same.
Resistance should be short circuit (zero resistance).
Note:
Design of APS may differ but test remains the same.

Isolate as per TOPs P4
and refit as necessary