Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Gain access to PCB (use Insulation Mat as required)
Selector Switch ON
Gas Control Knob in Main Burner position
Selector Switch ON
Gas Control Knob in Main Burner position
Gas On; Pilot On
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure voltage across Modulation Coil connections (Purple & Orange wires) on connector CN1.
The voltage should be greater than 16V AC.
The voltage should be greater than 16V AC.

Isolate as per TOPs P4
and refit as necessary