Set Appliance State:
Gas Off
Isolate Mains Power to appliance as per TOPs P4
Unplug connector CN4
Unplug connector CN4
Measurement:
Selector Switch Off.
Check for open circuit resistance across Selector microswitch (Black wires) on connector block CN4.
Selector Switch On.
Check for short circuit resistance across Selector microswitch (Black wires) on connector block CN4.
Replace connector CN4.
Note:
This test should be carried out on the disconnected connector not on the PCB.
Check for open circuit resistance across Selector microswitch (Black wires) on connector block CN4.
Selector Switch On.
Check for short circuit resistance across Selector microswitch (Black wires) on connector block CN4.
Replace connector CN4.
Note:
This test should be carried out on the disconnected connector not on the PCB.

Isolate as per TOPs P4
and refit as necessary