Set Appliance State:
Mains Power Off
Gas Off
CH Demand
Selector Switch ON
Gas Control Knob in Main Burner position
Gas Control Knob in Main Burner position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure voltage across Modulation Coil connections
(Purple & Orange wires) on connector CN1.
The voltage should be greater than 16 Volts AC.
(Purple & Orange wires) on connector CN1.
The voltage should be greater than 16 Volts AC.

Isolate as per TOPs P4
and refit as necessary