Set Appliance State:
Mains Power Off
Gas Off
Selector Switch OFF
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Test 1:
Measure approximately 24V AC across connector CN1 connections 6 (White) and 7 (Red).
Test 2:
Measure approximately 6V AC across connector CN1 connections 1 (Purple) and 2 (Orange).
Measure approximately 24V AC across connector CN1 connections 6 (White) and 7 (Red).
Test 2:
Measure approximately 6V AC across connector CN1 connections 1 (Purple) and 2 (Orange).

Isolate as per TOPs P4
and refit as necessary