Set Appliance State:
Mains Power Off
Gas On; Pilot On
Selector Switch OFF
Gas Control Knob in Main Burner position
Gas Control Knob in Main Burner position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
After 30 seconds of operation measure the slow fan voltage across connections 4 (Fan L, red wire) and connection 3
(Fan N, purple wire) on connector CN2.
This should be in the range 160-180 Volts AC.
(Fan N, purple wire) on connector CN2.
This should be in the range 160-180 Volts AC.

Isolate as per TOPs P4
and refit as necessary