Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Attach U gauge to inlet pressure test point
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Run the appliance in service mode (chimney sweep) allow the burner to ignite and establish.
Observe the U gauge and press the service mode button once to extinguish the flame.
The gauge should return to standing pressure immediately as soon as the demand ceases.
Note:
Upon completing of the test the test point should be tightened and checked for gas soundness.
Observe the U gauge and press the service mode button once to extinguish the flame.
The gauge should return to standing pressure immediately as soon as the demand ceases.
Note:
Upon completing of the test the test point should be tightened and checked for gas soundness.