Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect fan connector ST5 from the PCB
Measurement:
Test 1:
Place the black test probe on the brown wire and then measure the resistance to each of the test points listed in the table below at the disconnected fan connector ST5.
Resistances should conform approximately to the table below:
Test 2:
Measure the resistance between each wire to a suitable earth point.
Expect 1Mohm or greater on each test.
(OL is acceptable because it is greater than 1Mohm)
Are the resistances measured as expected?
Place the black test probe on the brown wire and then measure the resistance to each of the test points listed in the table below at the disconnected fan connector ST5.
Resistances should conform approximately to the table below:
| Test Leads | Resistance |
| Brown - Purple | Greater than 1 MOhms |
| Brown - Orange | Greater than 1 MOhms |
| Brown - Yellow | Greater than 1 MOhms |
| Brown - White | Greater than 1 MOhms |
Test 2:
Measure the resistance between each wire to a suitable earth point.
Expect 1Mohm or greater on each test.
(OL is acceptable because it is greater than 1Mohm)
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary