Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove pump cable from the pump
Disconnect the pump cable at the inline connector
Disconnect the pump cable at the inline connector
Measurement:
Test 1.
Measure the resistance between pin 1 on the pump connector
to pin 1 on the pump inline connector.
Test 2.
Measure the resistance between pin 2 on the pump connector
to pin 2 on the pump inline connector.
Test 3.
Measure the resistance between pin 3 on the pump connector
to pin 3 on the pump inline connector.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the harness.
Measure the resistance between pin 1 on the pump connector
to pin 1 on the pump inline connector.
Test 2.
Measure the resistance between pin 2 on the pump connector
to pin 2 on the pump inline connector.
Test 3.
Measure the resistance between pin 3 on the pump connector
to pin 3 on the pump inline connector.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the harness.

Isolate as per TOPs P4
and refit as necessary