Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
NO demand
Remove connector ST17 from PCB
Note.
Appliance may try to operate for preheat, this does not affect
the test results
Remove connector ST17 from PCB
Note.
Appliance may try to operate for preheat, this does not affect
the test results
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Test 1:
Measure the voltage across pin 2 at location ST17 on the PCB and the DC Neutral terminal.
Test 2:
Measure the voltage across pin 5 at location ST17 on the PCB and the DC Neutral terminal.
Expected voltage approximately 27V DC on both tests.
Measure the voltage across pin 2 at location ST17 on the PCB and the DC Neutral terminal.
Test 2:
Measure the voltage across pin 5 at location ST17 on the PCB and the DC Neutral terminal.
Expected voltage approximately 27V DC on both tests.

Isolate as per TOPs P4
and refit as necessary