Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:


Test 1: (5 vdc)
Approximately 5V DC expected at the two exposed
test points above the white connector ST17.
Note:
There are different PCB versions, choose correct test
from below.