Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
NO demand
ECO mode ON (illuminated)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Step 1:
Measure the voltage across pin 1 of ST17 and mains neutral. Expected voltage 15V DC. (A voltage of up to 30V DC may be measured initially but this should decrease and settle at approximately 15V DC)
Step 2:
Press and hold the reset button on the control panel for 2 seconds and then release, the voltage should then drop away and return to 15V DC.
Step 3:
Repeat Steps 1 and 2 at the following locations