Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove the ignition harness connection from the electrodes top of the burner and from the PCB

Measurement:

Measure the resistance of the ignition harness, PCB connections to the corresponding spark electrode connection.
Expected resistance 2.3 kOhms.