Set Appliance State:
ECO mode ON
Ensure NO demand
Ensure NO demand
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
While measuring for AC voltage across connector ST4 on the PCB, expect mains voltage, press and hold the reset button for at least 5 seconds then release, voltage should drop to zero.
Note:
Following the set-up instructions for this test is critical for correct diagnosis. Failure to turn off the preheat function or failure to remove any other demand will result in misdiagnosis.

Isolate as per TOPs P4
and refit as necessary