Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Gain access to PCB (use Insulation Mat as required)
Ensure primary heat exchanger is below 40°C (to ensure a demand for preheat)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

If required reset appliance (press and hold reset button for 5 seconds, then release).
Turn ECO mode OFF (press and hold the ECO button until it is no longer illuminated).
This turns the pre heat function ON.
Measure for mains voltage across brown and blue of ST4 pump connector on the pcb.