Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect pump plugs from PCB
Measurement:
Measure the resistance of the pump wires to the pump neutral (blue wire).
Resistances should be approximately as below:
Brown to neutral: 11.3kΩ
White to neutral: 2.2kΩ
Purple to neutral: Greater than 1MΩ
Black to neutral: 3.2kΩ
Resistances should be approximately as below:
Brown to neutral: 11.3kΩ
White to neutral: 2.2kΩ
Purple to neutral: Greater than 1MΩ
Black to neutral: 3.2kΩ

Isolate as per TOPs P4
and refit as necessary