Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Remove lower facia panel
Service mode potentiometer set to MAX
Gas On
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow fan to run and burner to ignite.
After approximately 8 seconds measure the voltage across the terminals of the modulating solenoid (blue wires).
Is approximately 8 Volts DC present across the terminals of the solenoid?