Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
On the test pins behind plug ST16 measure the voltage across pin 1 and 3 (white and black wires on connector) with the connector attached to the PCB using the long shrouded probes.
Expect approx. 5V DC.
Note:
Plug shown for clarity.
Expect approx. 5V DC.
Note:
Plug shown for clarity.

Isolate as per TOPs P4
and refit as necessary