Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Disconnect leads from fan assembly (note connections for reinstatement)
Disconnect leads from fan assembly (note connections for reinstatement)
Measurement:
Measure for resistance across fan terminals.
Expected resistance readings should conform to the appropriate table below:
                         (for RD628 use 28kW values)
Expected resistance readings should conform to the appropriate table below:
| 24 Si 2 | |
| Terminal | Resistance in Ohms | Black - Red | (approx.) 48 Ohms |
| Black - White | (approx.) 128 Ohms |
| 28 Si 2 | |
| Terminal | Resistance in Ohms | Black - Red | (approx.) 27 Ohms |
| Black - White | (approx.) 128 Ohms |

Isolate as per TOPs P4
and refit as necessary