Set Appliance State:
Mains Power Off
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Appliance On/Off control set to ON position.
Measure the voltage at the top of fuse F2 and an earth.
Expected voltage should be approximately 10-28 volts AC.
Measure the voltage at the top of fuse F2 and an earth.
Expected voltage should be approximately 10-28 volts AC.

Isolate as per TOPs P4
and refit as necessary