Set Appliance State:
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
Gain access to PCB, use isolation mat as required
Gain access to PCB, use isolation mat as required
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Appliance On/Off control set to ON position.
TEST 1. Measure for mains voltage at connector ST1 right hand pin (red wire, fan high speed) and a suitable earth connection.
Expected voltage approx. 240vac.
TEST 2. Measure for AC voltage at connector ST1 left hand pin (black wire, fan neutral) and a suitable earth connection.
Expected voltage approx. 0 vac.
TEST 1. Measure for mains voltage at connector ST1 right hand pin (red wire, fan high speed) and a suitable earth connection.
Expected voltage approx. 240vac.
TEST 2. Measure for AC voltage at connector ST1 left hand pin (black wire, fan neutral) and a suitable earth connection.
Expected voltage approx. 0 vac.