Set Appliance State:

Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
CH potentiometer set to minimum
Remove the programmer cover or programmer (if fitted)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow fan to run and burner to ignite.
On the test pins behind plug ST16 measure the voltage across pins 15 & 16 (blue wires on connector).
Expect approximately 20 vdc or greater.