Set Appliance State:

Set Multimeter to Resistance Set meter to measure resistance
Isolate Mains Power to appliance as per TOPs P4
Appliance On/Off control set to Off position
Remove one of the wires from the DHW sensor

Measurement:

Measure the resistance across the terminals of the DHW sensor.
The resistance measured will depend upon the boiler temperature, the higher the temperature the lower the resistance.
The resistance should conform to the table below.
Temperature °CResistance in kOhms
15-2015.6-14.9
20-3014.9-10.8
30-4010.8-6.0
40-506.0-4.4
50-604.4-3.0
60-703.0-2.4
70-802.4-1.6

Reconnect wires after the test.