Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
CH temperature selector to MAX
Attach temperature clamp to the flow pipe near the APS
Attach temperature clamp to the flow pipe near the APS
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow the appliance to ignite and establish.
Monitor the appliance temperature.
Does the appliance reach a flow temperature of approximately 82°C then shut down, or does overheat occur?
Note:
To reduce time taken for this test you may wish to turn off some radiators.
Monitor the appliance temperature.
Does the appliance reach a flow temperature of approximately 82°C then shut down, or does overheat occur?
Note:
To reduce time taken for this test you may wish to turn off some radiators.