Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove the wires and tubes from the air pressure switch (noting their locations)
Connect the APS testing kit and FGA to the APS (positive connection)

Measurement:

Steadily increase the pressure using the syringe to that shown on the APS.
(pressure may be shown on rear of APS)
Measure the resistance between the 2 terminals.
Continuity / zero resistance should be measured.
Notes:
1. If continuity is not obtained it is permissible to increase the pressure by 50%.
2. 100 Pascals = 1mb / 50 Pascals = 0.5mb.