Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Remove connector (blue wires) from modulating solenoid
Boiler ON/OFF switch OFF
DHW temperature selector at MAX
Boiler ON/OFF switch OFF
DHW temperature selector at MAX
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Boiler ON/OFF switch ON.
Allow boiler to ignite and run for at least 4 seconds.
Measure voltage at disconnected connector.
Allow boiler to ignite and run for at least 4 seconds.
Measure voltage at disconnected connector.

Isolate as per TOPs P4