Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Observation:
Check air pressure switch tubes both at the fan and at the air pressure switch for kinks, blockages, condensation, splits, damage and correct connection.
Note:
Air pressure tubes are in 3 parts. Silicone tubes connect both the fan and the air pressure switch to the steel tubes that run up the rear L/H side of the appliance.
Ensure all sections of tubing are inspected as above.
Note:
Air pressure tubes are in 3 parts. Silicone tubes connect both the fan and the air pressure switch to the steel tubes that run up the rear L/H side of the appliance.
Ensure all sections of tubing are inspected as above.