Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Boiler ON/OFF Switch OFF
CH Temperature Selector OFF
DHW Temperature Selector to Max
Disconnect the multi-plug connector from Gas Valve
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Boiler ON/OFF Switch ON.
Allow Fan to run and ignition sequence to commence.
Check for Voltage across the grey and violet connections on the multi-plug.
Reconnect plug after test.
Note:
Voltage will only be present during the spark period of the ignition sequence.
The Boiler will go to lock-out after approximately 10 seconds, and will have to be reset.