Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Boiler ON/OFF Switch OFF
CH Temperature Selector OFF
DHW Temperature Selector OFF
Disconnect leads from Modulating Solenoid (blue leads)
CH Temperature Selector OFF
DHW Temperature Selector OFF
Disconnect leads from Modulating Solenoid (blue leads)
Measurement:
Measure resistance across the exposed terminals on the Modulating Solenoid. Resistance should be approximately 60 Ohms.
Reconnect leads after test.
Reconnect leads after test.

Isolate as per TOPs P4
and refit as necessary