G.C. Number 47 311 40
Case removal
Front panel - Remove by lifting off supports.
Inner Case - Ensure electricity supply to appliance is off, remove 4 screws and lift off.
Lower Front Facia Panel - Ensure electricity supply to appliance is off, remove 3 screws from base of panel and remove.
Facia Panel - Ensure electricity supply to appliance is off, remove 2 screws and hinge down taking care not to damage pressure gauge capillary tube or electrical connections.
Notes
The appliance has two lockout conditions:-
1. Type one can be reset by turning the electricity supply off and on again.
2. The other can only be reset by depressing the reset button on the facia panel for a minimum of 1 second (the electricity supply and boiler on/off switch must be on when button is depressed).