Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove bottom facia panel
Disconnect connector X3 from the PCB marked PUMP
Disconnect connector X3 from the PCB marked PUMP
Measurement:
Test 1:
Measure the resistance between the blue and brown wires on X3.
Resistance should be approximately 180 Ohms.
Test 2:
Measure the resistance between the
brown wire on X3 to a suitable earth point.
Resistance should be greater than 1M Ohm.
Measure the resistance between the blue and brown wires on X3.
Resistance should be approximately 180 Ohms.
Test 2:
Measure the resistance between the
brown wire on X3 to a suitable earth point.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4