Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Attach a U-gauge to the gas valve burner pressure test point
Remove one of the leads from the modulating solenoid (blue wire)
and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow fan to run and burner to ignite.
Does the burner fully cross light and remain alight at approximately
minimum pressure (refer to table) and does ignition sparking cease?
Notes:
1. Sparking may continue for approximately 8 seconds if burner does not establish
then lockout will occur this can be reset by turning mains power to boiler off and on again.
2. When U-gauge is removed pressure test point should be tightened & checked for gas soundness.