Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect plug connector (marked ST16) from PCB

Observation:

Check resistance across connections 17 & 18 (yellow wires)
The resistance depends on temperature and should conform to the table below:
Temperature °CResistance in kOhms
1019.9
2012.5
308.1
405.3
503.6
602.5
701.8
801.3