Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
CH temperature selector set at MAX
Attach U-gauge to gas valve outlet pressure test point
Heating system should be cold
Boiler ON/OFF switch ON
Attach U-gauge to gas valve outlet pressure test point
Heating system should be cold
Boiler ON/OFF switch ON
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Allow boiler to commence its ignition sequence and the burner to ignite.
Does burner ignite and run at 5.4mb for 2 minutes, then does the burner pressure ramp up
over 1 minute to its set pressure of 35.5mb?
Notes:
The boiler is fully modulating and pressure ramp up will only take place if the system is cold and does not reach a satisfactory temperature in the initial 2 minutes.
If system temperature rise is satisfactory no increase in burner pressure should be considered normal operation.
When U-gauge is removed pressure test point should be tightened & checked for gas tightness.
Does burner ignite and run at 5.4mb for 2 minutes, then does the burner pressure ramp up
over 1 minute to its set pressure of 35.5mb?
Notes:
The boiler is fully modulating and pressure ramp up will only take place if the system is cold and does not reach a satisfactory temperature in the initial 2 minutes.
If system temperature rise is satisfactory no increase in burner pressure should be considered normal operation.
When U-gauge is removed pressure test point should be tightened & checked for gas tightness.