Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Heating temperature selector to OFF
Hot water temperature selector to OFF
Heating temperature selector to OFF
Hot water temperature selector to OFF
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure voltage across connection 4 (live, brown wire) and connection 3 (neutral, blue wire) on connector X11 on the main PCB.

Isolate as per TOPs P4