Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector marked X1 from the main PCB
Measurement:
Turn hot tap ON.
Measure resistance across the blue and brown wire at the disconnected connector.
Resistance should be short circuit.
Turn hot tap OFF.
Measure resistance across the blue and brown wire at the disconnected connector.
Resistance should be open circuit.
Reconnect connector after test.
Measure resistance across the blue and brown wire at the disconnected connector.
Resistance should be short circuit.
Turn hot tap OFF.
Measure resistance across the blue and brown wire at the disconnected connector.
Resistance should be open circuit.
Reconnect connector after test.

Isolate as per TOPs P4
and refit as necessary