Set Appliance State:

Set Multimeter to Resistance Set meter to measure resistance
Isolate Mains Power to appliance as per TOPs P4
Selector switch to Water
Unplug connector X14 block (located at top left corner) from main driver board

Measurement:

Measure resistance between brown (central on switch) and white wires on selector switch.