Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
Boiler Operating Switch / Programmer set to WATER only
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
With the DHW tap fully open measure the DC voltage across connections 5 and 6 (Yellow wires) on connector X2 on the main PCB.
The voltage obtained should be greater than 20V DC.
The voltage obtained should be greater than 20V DC.

Isolate as per TOPs P4
and refit as necessary