Set Appliance State:

Set Multimeter to Resistance Set meter to measure resistance
Isolate Mains Power to appliance as per TOPs P4
Disconnect connector CN3 from Sequence Control PCB

Measurement:

Measure the resistance across connection MN (Brown wire) and connection ML (Blue wire) on the disconnected plug.
The resistance should be approximately 4.8Kohms.
Note 1:
Measurements taken at the disconnected plug not at the PCB.
Note 2:
On some models sequence control PCB may have only numbered connections in which connections will be numbered 11, 12 & 13 test to be carried out on Brown and Blue wires on the plug that were connected to connections 11 and 12.