Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Disconnect the two Pink wires from the Gas Valve Main Solenoid
Disconnect the two Pink wires from the Gas Valve Main Solenoid
Measurement:
Measure the resistance of the solenoid.
Resistance should be approximately 60 ohms.
Resistance should be approximately 60 ohms.

Isolate as per TOPs P4
and refit as necessary