Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove ignition / rectification electrode
(remove 2 black plugs on top of boiler casing, this will allow access to undo bolts with 3mm Allen key & pull electrode up and bend around heat exchanger)
(remove 2 black plugs on top of boiler casing, this will allow access to undo bolts with 3mm Allen key & pull electrode up and bend around heat exchanger)
Measurement:
Check electrode is in good overall condition:
Ceramic not cracked
Electrode not warped or distorted
Measure the resistance across the electrode (if needed clean tip of electrode to get a good connection).
Resistance should be short circuit (zero resistance).
Measure the resistance across the electrode (if needed clean tip of electrode to get a good connection).
Resistance should be short circuit (zero resistance).

Isolate as per TOPs P4
and refit as necessary